| 7625 West New York Street | ||
| Indianapolis, Indiana 46214-4911 USA | ||
| Telephone: (317) 273-6960 | ||
| Facsimile: (317) 273-6979 | ||
| Order Desk Telephone: (800) 401-1723 | ||
| Order Desk Facsimile: (800) 515-9254 | ||
| E-mail: flotec@floteco2.com | ||
|
REGULATOR SINGLE WINDOW |
||||||||||||
| FLOW RANGE | RANGE CODE |
FLOW SETTING AS THEY APPEAR THRU WINDOW |
||||||||||
| 1/10 thru 1.5 | A1 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | 1.5 |
| 1/32 thru 4 | D2 | 1/32 | 1/16 | 1/8 | 1/4 | 1/2 | 3/4 | 1 | 1 1/2 | 2 | 3 | 4 |
| 1/16 thru 4 | D4 | .06 | .12 | .25 | .5 | .75 | 1 | 1.5 | 2 | 2.5 | 3 | 4 |
| 1/32thru 5 | E1 | 0.03 | 0.06 | 0.12 | 0.25 | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 5 |
| 1/8 thru 6 | F1 | .12 | .25 | .5 | .75 | 1 | 1.5 | 2 | 3 | 4 | 5 | 6 |
| 1/2 thru 8 | H1 | 0.5 | 1 | 1.5 | 2 | 2.5 | 3 | 4 | 5 | 6 | 7 | 8 |
| 1/2 thru 10 | J1 | 0.5 | 1 | 1.5 | 2 | 2.5 | 3 | 4 | 5 | 6 | 8 | 10 |
|
6 thru 12 |
L4 |
- | 6 | - | 12 | - | - | - | - | - | - | - |
| 1/2 thru 15 | M1 | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 15 |
| 1/2 thru 15 | M5 | 0.5 | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 15 |
| 1/32 thru 15 | M6 | 1/32 | 1/16 | 1/8 | 1/4 | 1/2 | 3/4 | 1 | 1 1/2 | 2 | 6 | 15 |
| 1/4 thru 15 | MB | 1/4 | 1/2 | 1 | 1 1/2 | 2 | 3 | 4 | 6 | 8 | 12 | 15 |
| 6 thru 12 | MX | FLOW | CPR | - | - | - | - | - | - | - | - | - |
|
1/4 thru 25 |
P1 |
.25 |
.5 |
1 |
2 |
3 |
4 |
6 |
8 |
10 |
15 |
25 |
| 1/4 thru 25 | P2 | 1/4 | 1/2 | 1 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 25 |
| 1 thru 25 | P4 | 1 | 2 | 3 | 4 | 6 | 8 | 10 | 12 | 15 | 20 | 25 |
| 1 thru 25 | P5 | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 15 | 25 |
| 1 thru 25 | P7 | 1/2 | 1 | 1 1/2 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 25 |
| 8 thru 25 | PA | 8 | 12 | 15 | 25 | - | - | - | - | - | - | - |
| 1/4 thru 30 | Q1 | 0.25 | 0.5 | 1 | 2 | 4 | 6 | 8 | 10 | 12 | 20 | 30 |
| 4 thru 40 | Q7 | 4 | 6 | 8 | 10 | 12 | 15 | 20 | 25 | 30 | 35 | 40 |
| 1 thru 60 | T1 | 1 | 2 | 3 | 4 | 5 | 6 | 10 | 15 | 25 | 40 | 60 |
| REGULATOR DOUBLE WINDOW | ||||||||||||
| FLOW RANGE | RANGE CODE | FLOW SETTING AS THEY APPEAR THRU WINDOW | ||||||||||
| 20 ML thru 3 L | C4 | 20 | 25 | 50 | 100 | 250 | 500 | 750 | 1 | 1.5 | 2 | 3 |
| ML | ML | ML | ML | ML | ML | ML | L | L | L | L | ||
| 30 ML thru 4 L | D8 | 30 | 60 | 125 | 250 | 500 | 750 | 1 | 1.5 | 2 | 3 | 4 |
| ML | ML | ML | ML | ML | ML | L | L | L | L | L | ||
| MINI RIGHT HAND REGULATOR | ||||||||||||
| FLOW RANGE | RANGE CODE | FLOW SETTING AS THEY APPEAR THRU WINDOW | ||||||||||
| 1/2 thru 6 | F5 | 6.0 | 5.0 | 4.0 | 3.5 | 3.0 | 2.5 | 2.0 | 1.5 | 1.0 | 0.75 | 0.50 |
|
MINI LEFT HAND REGULATOR |
||||||||||||
| FLOW RANGE | RANGE CODE | FLOW SETTING AS THEY APPEAR THRU WINDOW | ||||||||||
| 1/2 thru 6 | F2 | 0.50 | 0.75 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 5.0 | 6.0 |
| 1/2 thru 8 | H4 | 0.5 | 1 | 1.5 | 2 | 2.5 | 3 | 4 | 5 | 6 | 7 | 8 |
| 1/2 thru 15 | M2 | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 15 |
| 1/2 thru 25 | P9 | 1/4 | 1/2 | 1 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 25 |
|
FLOWMETER SINGLE WINDOW |
||||||||||||
| FLOW RANGE | RANGE CODE | FLOW SETTING AS THEY APPEAR THRU WINDOW | ||||||||||
| 1/10 thru 1.5 | A3 | 1.5 | 1 | .90 | .80 | .70 | .60 | .50 | .40 | .30 | .20 | .10 |
| 1/10 thru 1.5 | A4 | 1.5 | 1.0 | 0.9 | 0.8 | 0.7 | 0.6 | 0.5 | 0.4 | 0.3 | 0.2 | 0.1 |
| 1/50 thru 3 | A5 | 3.00 | 1.00 | 0.75 | 0.50 | 0.30 | 0.20 | 0.12 | 0.08 | 0.05 | 0.03 | 0.02 |
| 1/40 thru 2 | B1 | 2.0 | 1.5 | 0.9 | 0.6 | 0.4 | 0.25 | 0.15 | 0.09 | 0.06 | 0.04 | 0.025 |
| 1/32 thru 4 | D1 | 4 | 3 | 2 | 1 1/2 | 1 | 3/4 | 1/2 | 1/4 | 1/8 | 1/16 | 1/32 |
| 1/32 thru 4 | D3 | 4 | 3 | 2 | 1.5 | 1.0 | 0.75 | 0.50 | 0.25 | 0.12 | 0.06 | 0.03 |
| 1/2 thru 6 | F3 | 6.0 | 5.0 | 4.0 | 3.5 | 3.0 | 2.5 | 2.0 | 1.5 | 1.0 | 0.75 | 0.50 |
| 1/2 thru 8 | H3 | 8 | 7 | 6 | 5 | 4 | 3 | 2.5 | 2 | 1.5 | 1 | .5 |
| 1/2 thru 15 | M3 | 15 | 10 | 8 | 6 | 5 | 4 | 3 | 2 | 1.5 | 1 | .5 |
| 1/32 thru 15 | M4 | 15 | 6 | 2 | 1 1/2 | 1 | 3/4 | 1/2 | 1/4 | 1/8 | 1/16 | 1/32 |
| 1/2 thru 15 | M7 | 15 | 12 | 10 | 8 | 6 | 5 | 4 | 3 | 2 | 1 | 1/2 |
| 1/4 thru 15 | M8 | 15 | 12 | 8 | 6 | 4 | 3 | 2 | 1 1/2 | 1 | 1/2 | 1/4 |
| 1/16 thru 15 | M9 | 15 | 10 | 8 | 5 | 3 | 2 | 1 | 0.50 | 0.25 | 0.12 | 0.06 |
| 4 thru 15 | MA | 15 | 14 | 13 | 12 | 11 | 10 | 8 | 7 | 6 | 5 | 4 |
| 1/8 thru 16 | N1 | 16 | 8 | 6 | 2.5 | 2 | 1.5 | 1 | 3/4 | 1/2 | 1/4 | 1/8 |
| 1/4 thru 25 | P3 | 25 | 15 | 10 | 8 | 6 | 4 | 3 | 2 | 1 | .5 | .25 |
| 1 thru 25 | P6 | 25 | 20 | 15 | 12 | 10 | 8 | 6 | 4 | 3 | 2 | 1 |
| 1/2 thru 25 | P8 | 25 | 15 | 10 | 8 | 6 | 4 | 3 | 2 | 1 1/2 | 1 | 1/2 |
| 1 thru 25 | PB | 25 | 15 | 12 | 10 | 8 | 6 | 5 | 4 | 3 | 2 | 1 |
| 10 thru 40 | Q5 | 40 | 38 | 35 | 32 | 30 | 28 | 25 | 22 | 20 | 15 | 10 |
| 1/4 thru 60 | S1 | 40 | 15 | 10 | 8 | 6 | 5 | 4 | 3 | 2 | 1 | 0.5 |
| 1/4 thru 60 | T2 | 60 | 25 | 10 | 8 | 6 | 4 | 3 | 2 | 1 | 0.50 | 0.25 |
| 1/4 thru 60 | T3 | 60 | 40 | 15 | 10 | 8 | 6 | 2 | 1 | 0.75 | 0.50 | 0.25 |
|
FLOWMETER DOUBLE WINDOW |
||||||||||||
| FLOW RANGE | RANGE CODE | FLOW SETTING AS THEY APPEAR THRU WINDOW | ||||||||||
| 25 ML thru 1 L | A2 | 1 | 500 | 250 | 200 | 175 | ||||||